Product specification

Items G300
Power Rated voltage, Frequency
Supply One-phase/Three-phase AC 220V 50/60Hz
Voltage Range
220V: 170~240V
Output Voltage Range 220V: 0~220V
Frequency Range 0.10~400.00Hz
Control method V/F control, Space vector control.
Indication Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on.
            Control   SpeciAlations Output Frequency 0.10Hz~400.00Hz
Range
Frequency Setting Digital input: 0.01Hz, analog input: 0.1% of
Resolution maximum output frequency
Output Frequency 0.01Hz
Accuracy
V/F Control Setting V/F curve to satisfy various load
Requirements.
Torque Auto increase: auto raise torque by loading
Control Condition; Manual increase: enable to set
0.0~20.0% of raising torque.
Multifunctional Four multi-function input terminals, realizing
Input Terminal functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions
Multifunctional 1 multi-function output terminals for displaying
Output Terminal of running, zero speed, counter, external
abnormity, program operation and other
Information and warnings.
Acceleration/ deceleration Time Setting 0~999.9s acceleration/deceleration time can be set individually.
                 Other      functions PID Control Built-in PID control
RS485 Standard RS485 communication function(MODBUS)
Frequency Setting Analog input: 0 to 10 V, 0 to 20mA can be
selected;
Digital input:Input using the setting dial of the
operation panel or RS485 or UP/DOWN.
Note:AVI terminals can be used to select an
analog voltage input(AV) and analog current
input(AI) through the switch J2.
Note: AVI terminals can be used to select an
Analog voltage input (AV) and analog current
Input(AI) through the switch J2.
Multi-speed Four multifunction input terminals, 15 section
speed can be set
Automatic Automatic voltage regulation function can be
voltage ID ControlliAlation  regulation Selected
Counter Built-in 2 group of counters
   Protection/Warning       Function              Overload 150%, 60 second(Constant torque)
Over Voltage Over voltage protection can be set.
Under Voltage Under voltage protection can be set
Other Protections Overheat,output short circuit,over current, and
Parameter lock and so on.
   Environment Ambient Temperature -10℃ to 40℃(non-freezing)
Ambient Humidity Max. 95% (non-condensing)
Altitude Lower than 1000m
Vibration Max.0.5G
Structure Cooling Mode Forced air cooling
Protective IP 20
Structure
Installation Mode Wall-mounted or standard 35MM rail mounting