S2100E
Product description: power range : 5.5kW-280kW 380V
Advantage: Constant pressure
Similar as ABB510 series
Support multi-pump at most 5 pumps
Dormancy pump/auto-stop without water/calendar etc
Product Details:
Items |
S2100 E |
||
Power Supply |
Rated voltage, Frequency |
Single phase/Three phase 220V 50/60Hz Single-phase 220V 50/60Hz |
|
Voltage Range |
380V:330V~440V; 220V:170V~240V |
||
Output |
Voltage Range |
380V:0~380V; 220V:0~220V |
|
Frequency Range |
0.10`400.00Hz |
||
Control method |
V/F control, Space vector control. |
||
Indication |
Operating status/Alarm definition/interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. |
||
Control Specifications |
Output Frequency Range |
0.10Hz~400.00Hz |
|
Frequency Setting Resolution |
Digital input:0.01Hz, analog input:0.1% of maximum output frequency |
||
Output Frequency Accuracy |
0.01Hz |
||
V/F Control |
Setting V/F curve to satisfy various load requirements |
||
Torque Control |
Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque |
||
Multifunctional Input Terminal |
Eight multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
||
Multifunctional Output Terminal |
3 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings |
||
Acceleration/deceleration time Setting |
0~-6000s acceleration/deceleration time can be set individually |
||
Other Functions |
PID Control |
Built-in PID control |
|
RS485 |
Standard RS485 communication function(MODBUS) |
||
Frequency Setting |
Analog input:0 to 10V,,0 to 20mA can be selected;z Digital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
||
Multi-speed |
Eight multifunction input terminals, 15section speed can be set |
||
Automatic voltage regulation |
Automatic voltage regulation function can be selected |
||
Counter |
Built –in 2group of counters |
||
Protection Warning Function |
Overload |
150%,60 second(Constant torque);120%.60 second (variable torque) |
|
Over Voltage |
Over voltage protection can be set |
||
Under Voltage |
Under voltage protection can be set |
||
Other Protections |
Overheat, short circuit, over current, and parameter lock and so on |
||
Environment |
Ambient Temperature |
-10℃ to 40℃(non-freezing) |
|
Ambient Humidity |
Max.95%(non-condensing) |
||
Altitude |
Lower than 1000m |
||
Vibration |
Max. 0.5G |
||
Structure |
Cooling Mode |
Forced air cooling |
|
Protective Structure |
IP20 |
||
Installation |
Mode |
Below 90KW:Wall Mounted; 110~200KW:Wall Mounted or in Cabinet; Above 220KW:in Cabinet |