General vector control(IM)(S3100A)
General vector control(IM)(S3100A)
Rated Voltage:Single 220V/3phase 220V/3phase 440V
Frequency range:0~500Hz(Can be set to 3200Hz)
Power range:0.4~500kW
220V single phase/three phase Sereis |
||||||||||||||||||
|
Item |
Specification |
- |
|||||||||||||||
S3100A-2T***G |
0.4 |
0.75 |
1.5 |
2.2 |
4 |
5.5 |
7.5 |
|||||||||||
output |
Maximum applicable motor output power(kW) |
0.4 |
0.75 |
1.5 |
2.2 |
4 |
5.5 |
7.5 |
||||||||||
Maximun applicable motor output power(HP) |
0.5 |
1 |
2 |
3 |
5.4 |
7.4 |
1 |
|||||||||||
Output rated capacity(kVA) |
1.1 |
1.5 |
2.7 |
3.7 |
6.5 |
9.5 |
12.2 |
|||||||||||
Output rated current(A) |
2.3 |
4 |
7 |
9.6 |
17 |
25 |
32 |
|||||||||||
Output frquency range |
0-500Hz |
|||||||||||||||||
overload capacity |
15%-60s |
|||||||||||||||||
max output voltage |
same to input voltage |
|||||||||||||||||
input |
Phase,voltage , frequency |
single phase /three phase. 200~240V. 50/60Hz |
||||||||||||||||
Voltage frequency variations |
voltage: ±15% frequency: ±5% |
|||||||||||||||||
input current (A) |
single phase |
5.4 |
8.2 |
14.2 |
23 |
no single phase input |
- |
|||||||||||
three phase |
3.1 |
5 |
7.7 |
11.1 |
22.2 |
31.5 |
42.7 |
|||||||||||
cooling method |
fan cooling |
|||||||||||||||||
Three phase 440v series |
- |
|||||||||||||||||
Item |
specification |
|||||||||||||||||
S3100A-4T***G |
0.75 |
1.5 |
2.2 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
|||
output |
Maximum applicable motor output power(kW) |
0.75 |
1.5 |
2.2 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
||
Maximun applicable motor output power(HP) |
1 |
2 |
3 |
5.4 |
7.4 |
10 |
14.7 |
20 |
24.7 |
29.4 |
40 |
50 |
60 |
74 |
100 |
|||
Output rated capacity(kVA) |
1.9 |
2.9 |
3.9 |
6.9 |
9.9 |
13 |
19.1 |
24.4 |
28.2 |
34.3 |
45.7 |
57.1 |
68.6 |
83.8 |
114.3 |
|||
Output rated current(A) |
2.5 |
3.8 |
5.1 |
9 |
13 |
17 |
25 |
32 |
37 |
45 |
60 |
75 |
90 |
110 |
152 |
|||
-3.2 |
-4.7 |
-6.5 |
-11.8 |
-15 |
-21.7 |
-28.5 |
-35.4 |
-42 |
-60 |
-75 |
-85 |
-110 |
-150 |
-176 |
||||
Output rated current(A) |
0-500Hz |
|||||||||||||||||
Overload capacity |
G type :150%-60 seconds |
|||||||||||||||||
P type 120%-60 seconds |
||||||||||||||||||
max output voltage |
same to input voltage |
|||||||||||||||||
Input |
Phase,voltage , frequency |
Three phase :380-460v 50/60Hz |
||||||||||||||||
voltage frequency variations |
voltage :±15% frequency: ±5% |
|||||||||||||||||
input current (A) |
3.4 |
5 |
5.8 |
10.5 |
15 |
20.5 |
26 |
35 |
38 |
46 |
62 |
76 |
92 |
113 |
157 |
|||
cooling method |
fan cooling |
|||||||||||||||||
|
Item |
specification |
- |
|||||||||||||||
|
S3100A-4T***G |
90 |
110 |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
||||||||
output |
Maximum applicable motor output power(kW) |
90 |
110 |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
||||||||
Maximun applicable motor output power(HP) |
120 |
147 |
176 |
214 |
247 |
267 |
294 |
334 |
374 |
|||||||||
Output rated capacity(kVA) |
134 |
160 |
191 |
229 |
259 |
290 |
316 |
358 |
358 |
|||||||||
Output rated current(A) |
176 |
210 |
253 |
304 |
340 |
377 |
426 |
465 |
520 |
|||||||||
-210 |
-253 |
-304 |
-340 |
-377 |
-426 |
-465 |
-520 |
-585 |
||||||||||
Output frquency range |
0-500Hz |
|||||||||||||||||
overload capacity |
G type :150%-60 seconds |
|||||||||||||||||
P type 120%-60 seconds |
||||||||||||||||||
max output voltage |
same to input voltage |
|||||||||||||||||
input |
Phase,voltage , frequency |
three phase :380-460V 50/60HZ |
||||||||||||||||
Voltage frequency variations |
voltage :±15% frequency: ±5% |
|||||||||||||||||
input current (A) |
180 |
214 |
256 |
308 |
345 |
382 |
430 |
470 |
525 |
|||||||||
cooling method |
fan cooling |
|||||||||||||||||
|
Item |
Detailed information |
||||||||||||||||
control characteristic |
control mode |
V/F control , open loop vector control , torque control |
||||||||||||||||
range of output frequency |
0-500.00Hz(v/f highest 3200.0Hz) |
|||||||||||||||||
frequency setting resolution |
0.01Hz |
|||||||||||||||||
ouput frequency setting resolution |
0.01Hz |
|||||||||||||||||
PWM carrier frequency |
adjust from 0.5Khz to 12khz |
|||||||||||||||||
torque boost |
open loop vector control(SVC):G type:0.5Hz/150%,P type 0.5Hz/120% |
|||||||||||||||||
V/F curve |
three types :line, multi-point. Nth power v/f curve |
|||||||||||||||||
(1.2th power ,1.4th power ,1.6th power , 1.8th power ,2th power |
||||||||||||||||||
v/f separation |
twp types : full separation , semi-separation |
|||||||||||||||||
Jump frequency |
adjust from 0.1hz to 500.00hz |
|||||||||||||||||
acceleration/deceleration time |
0.00 to 65000 seconds(4-stage acceleration/deceleration time is set independently)linear or S-curve acceleration/deceleration mode |
|||||||||||||||||
over current stall prevention level |
can be set according to the motor load characteristics with 100-200% of the rated current of the driver |
|||||||||||||||||
DC brake |
when stopping , it can be operated from 0.00 to the maximum operating frequency , and the braking current is 0 to 100% of the rated current;Start time 0-100.0 seconds, stop time 0-100.0 seconds |
|||||||||||||||||
Brake torque |
20%(external optional brake resistor can reach 125%) |
|||||||||||||||||
(1-30HP brake transistor built-in,40HP and above can be connected to the external brake unit module |
||||||||||||||||||
operation charactreistic |
Speed ratio |
open loop vector control :1:100 |
||||||||||||||||
Frequency setting signal |
bit operation board :set by |
|||||||||||||||||
external terminal :0-10VDC,4-20mADC, Serial communication(RS485) |
||||||||||||||||||
Operation signal |
bit operation board :Available to be oerated by RUN, STOP, JOG keys |
|||||||||||||||||
external terminal :2-wire/ 3-wire operation ,jog operation , serial communication(RS485) |
||||||||||||||||||
Input terminal of multi-function |
Forward and reverse running, three-wire operaton control, Forward and reverse jog running,free stop, reset fault, running pause, external fault input, increment /decrement frequency terminal setting,16-segment prese speed switching,acceleration/deceleration time switching ,frequency |
|||||||||||||||||
source switching, running command switching,PID control, PLC status |
||||||||||||||||||
reset, pause swing frequency, reset swing frequency, prohibit acceleration and deceleration, disable torque control, calculator function, length count frequency increase and decrease setting clear, high speed pulse |
||||||||||||||||||
frequency , stop DC braking, frequency modification enable, speed control and torque control switching, clear running time of this time. |
||||||||||||||||||
|
||||||||||||||||||
output terminal of multi-function |
Inverter operation, fault output, frequency level detection FDT output |
|||||||||||||||||
frequency arrival, zero speed operation,overload pre-alarm count value arrival length arrival, PLC cycle completion, cumulative running time |
||||||||||||||||||
Item |
Detailed information |
|||||||||||||||||
|
arrival ,frequency limitation , torque limit ready to run , ACI1>AVI2, upper limit frequency arrival ,lower limit frequency arrival(operation related). undervoltage status output, communication setting , cumulative power-on time arrival , frequency arrival output , timing arrival output, offload , recerse |
|||||||||||||||||
In operation , the zero current state, the module temperature reaches , the output current exceeds the limt, the lower limit frequency arrives(the stop is also output ) the alarm output (contrinues to run ) and the running time arrives |
||||||||||||||||||
analog signal output |
corresponding to the actual output frequency , output current , output voltage,etc. |
|||||||||||||||||
fault signal contact |
contact"ON"(one "C" contract relay or two open collector outputs when the AC drive fails |
|||||||||||||||||
inner function |
Output frequency upper and lower limit seing, instantaneous power failure restart abnormal fault restart speed tracking |
|||||||||||||||||
Simple PLC.multi-speed operation,PID control, timing control Automatic regulated output regulation |
||||||||||||||||||
Abnormal record. parameter lock, parameter factory reset |
||||||||||||||||||
Reverse rotation prohibited,overcurent stall prevention, overvoltage stall prevention, electronic thermal relay |
||||||||||||||||||
|
||||||||||||||||||
protection function |
Short circuit protection, acceleration over current, deceleration over current, constant speed over current, acceleration over voltage. |
|||||||||||||||||
deceleration over voltage, constant speed over voltage, bus undervoltage fault. motor overload. inverter overload. over torque protection, loss phase protection function on the input (7.5G/11P and above),loss phase on the output , module |
||||||||||||||||||
overheating. external fault, communication fault, current detection fault. motor self-leaming faut, parameter read and write abnormality, inverter hardware abnormality, motor short circuit to ground., running time arrival. the power-on time arrives, the load dropped. the PID feedback disconnected. and the fast current limit timeout |
||||||||||||||||||
|
number of part on keypad |
Contains 8 function keys,5-digit8-segment LED display,7 status indicato LED lightsCan set the frequency,display the actual output frequency. |
||||||||||||||||
output current, user-defined unit Parameter browsing and modification settings and parameter locking,abnormal fault display |
||||||||||||||||||
Executable operation, stop,reset, forward/reverse, jogging |
||||||||||||||||||
environment |
operation temperature |
_10℃ to + 50℃( + 40℃~ + 50℃ below 90% RH, No condensation) |
||||||||||||||||
temperature of stock |
.-20℃ to .+60℃ |
|||||||||||||||||
humidity of opeation environment |
belowe 90%RH,NO condenstaion |
|||||||||||||||||
height of installtion |
no more than 1000m in height, no corrorsive gas, liquid , dust |
|||||||||||||||||
vibation |
Below 20Hz 9.80665m/s²(1g), 20-50Hz 5.88m/s²(0.6g) |
|||||||||||||||||
enclosure |
IP20(Depending on the end customers`s installation environment) |
|||||||||||||||||
Note: the instantaneous power failure compensation time varies due to the inverter capacity.If a long instataneouspower failure time is required, the external"instantaneous power failure compensation device can be added |