General vector control(IM)(S3100A)

General vector control(IM)(S3100A)
Rated Voltage:Single 220V/3phase 220V/3phase 440V
Frequency range:0~500Hz(Can be set to 3200Hz)
Power range:0.4~500kW

220V single phase/three phase Sereis

Item

Specification

-

S3100A-2T***G

0.4

0.75

1.5

2.2

4

5.5

7.5

output

Maximum applicable motor output power(kW)

0.4

0.75

1.5

2.2

4

5.5

7.5

Maximun applicable motor output power(HP)

0.5

1

2

3

5.4

7.4

1

Output rated capacity(kVA)  

1.1

1.5

2.7

3.7

6.5

9.5

12.2

Output rated current(A)

2.3

4

7

9.6

17

25

32

Output frquency range

0-500Hz

overload capacity

15%-60s

max output voltage

same to input voltage

input

Phase,voltage , frequency

single phase /three phase. 200~240V. 50/60Hz

Voltage frequency variations

voltage: ±15% frequency: ±5%

input current (A)

single phase

5.4

8.2

14.2

23

no single phase input

-

three phase

3.1

5

7.7

11.1

22.2

31.5

42.7

cooling method

fan cooling

Three phase 440v series

-

Item

specification

S3100A-4T***G

0.75

1.5

2.2

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

output

Maximum applicable motor output power(kW)

0.75

1.5

2.2

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

Maximun applicable motor output power(HP)

1

2

3

5.4

7.4

10

14.7

20

24.7

29.4

40

50

60

74

100

Output rated capacity(kVA)  

1.9

2.9

3.9

6.9

9.9

13

19.1

24.4

28.2

34.3

45.7

57.1

68.6

83.8

114.3

Output rated current(A)

2.5

3.8

5.1

9

13

17

25

32

37

45

60

75

90

110

152

-3.2

-4.7

-6.5

-11.8

-15

-21.7

-28.5

-35.4

-42

-60

-75

-85

-110

-150

-176

Output rated current(A)

0-500Hz

Overload capacity

G type :150%-60 seconds

P type 120%-60 seconds

max output voltage

same to input voltage

Input

Phase,voltage , frequency

Three phase  :380-460v 50/60Hz

voltage frequency variations

voltage :±15%  frequency: ±5%

input current (A)

3.4

5

5.8

10.5

15

20.5

26

35

38

46

62

76

92

113

157

cooling method

fan cooling

Item

specification

-

S3100A-4T***G

90

110

132

160

185

200

220

250

280

output

Maximum applicable motor output power(kW)

90

110

132

160

185

200

220

250

280

Maximun applicable motor output power(HP)

120

147

176

214

247

267

294

334

374

Output rated capacity(kVA)  

134

160

191

229

259

290

316

358

358

Output rated current(A)

176

210

253

304

340

377

426

465

520

-210

-253

-304

-340

-377

-426

-465

-520

-585

Output frquency range

0-500Hz

overload capacity

G type :150%-60 seconds

P type 120%-60 seconds

max output voltage

same to input voltage

input

Phase,voltage , frequency

three phase :380-460V 50/60HZ

Voltage frequency variations

voltage :±15%  frequency: ±5%

input current (A)

180

214

256

308

345

382

430

470

525

cooling method

fan cooling

Item

Detailed information

control characteristic

control mode

V/F  control , open loop vector control , torque control

range of output frequency

0-500.00Hz(v/f highest 3200.0Hz)

frequency setting resolution

0.01Hz

ouput frequency setting resolution

0.01Hz

PWM carrier frequency

adjust from 0.5Khz to 12khz

torque boost

open loop vector control(SVC):G type0.5Hz/150%,P type 0.5Hz/120%

V/F curve

three types :line, multi-point. Nth power v/f curve

(1.2th power ,1.4th power ,1.6th power ,  1.8th power ,2th power

v/f separation

twp types : full separation , semi-separation

Jump frequency

adjust from 0.1hz to 500.00hz

acceleration/deceleration time

0.00 to 65000 seconds(4-stage acceleration/deceleration time is set independently)linear or S-curve acceleration/deceleration mode

over current stall prevention level

can be set according to the motor load characteristics with 100-200% of the rated current of the driver

DC brake

when stopping , it can be operated from 0.00 to the maximum operating frequency , and the braking current is 0 to 100% of the rated current;Start time 0-100.0 seconds, stop time 0-100.0 seconds

Brake torque

20%(external optional brake resistor can reach 125%)

(1-30HP brake transistor built-in,40HP and above can be connected to the external brake unit module

operation charactreistic

Speed ratio

open loop vector control :1:100

Frequency  setting signal

bit operation board :set by

external terminal :0-10VDC,4-20mADC, Serial communication(RS485)

Operation signal

bit operation board :Available to be oerated by RUN, STOP, JOG keys

external terminal :2-wire/ 3-wire operation ,jog operation , serial communication(RS485)

Input terminal of multi-function

Forward and reverse running, three-wire operaton control, Forward and reverse jog running,free stop, reset fault, running pause, external fault input, increment /decrement frequency terminal setting,16-segment prese speed switching,acceleration/deceleration time switching ,frequency

source switching, running command switching,PID control, PLC status

 reset, pause swing frequency, reset swing frequency, prohibit acceleration and deceleration, disable torque control, calculator function, length count frequency increase and decrease setting clear, high speed pulse

 frequency , stop DC braking, frequency modification enable, speed control and torque control switching, clear running time of this time.

output terminal of multi-function

Inverter operation, fault output, frequency level detection FDT output

 frequency arrival, zero speed operation,overload pre-alarm count value arrival length arrival, PLC cycle completion, cumulative running time

Item

Detailed  information

arrival ,frequency limitation , torque limit ready to run , ACI1AVI2 upper limit frequency  arrival ,lower limit frequency arrival(operation related). undervoltage status output, communication setting , cumulative power-on time arrival , frequency arrival output , timing arrival output, offload , recerse

In operation , the zero current state, the module temperature reaches , the output current exceeds the limt, the lower limit frequency  arrives(the stop is also output ) the alarm output (contrinues to run ) and the running time arrives

analog signal output

corresponding to the actual output frequency , output current , output voltage,etc.

fault signal contact

contact"ON"(one "C" contract relay or two open collector outputs when the AC drive fails

inner function

 Output frequency upper and lower limit seing, instantaneous power failure restart abnormal fault restart speed tracking

 Simple PLC.multi-speed operation,PID control, timing control Automatic regulated output regulation

 Abnormal record. parameter lock, parameter factory reset

 Reverse rotation prohibited,overcurent stall prevention, overvoltage stall prevention, electronic thermal relay

protection function

Short circuit protection, acceleration over current, deceleration over current, constant speed over current, acceleration over voltage.

 deceleration over voltage, constant speed over voltage, bus undervoltage fault. motor overload. inverter overload. over torque protection, loss phase protection function  on the input (7.5G/11P and above),loss phase on the output , module

 overheating. external fault, communication fault, current detection fault. motor self-leaming faut, parameter read and write abnormality, inverter hardware abnormality, motor short circuit to ground., running time arrival. the power-on time arrives, the load dropped. the PID feedback disconnected. and the fast current limit timeout

 number of part on keypad

Contains 8 function keys,5-digit8-segment LED display,7 status indicato LED lightsCan set the frequency,display the actual output frequency.

output current, user-defined unit Parameter browsing and modification settings and parameter locking,abnormal fault display

Executable operation, stop,reset, forward/reverse, jogging

environment

operation  temperature

_10 to + 50℃( + 40~ + 50 below 90% RH, No condensation)

temperature of stock

.-20 to .+60

humidity of opeation environment

belowe 90%RH,NO  condenstaion

height  of installtion

no more than 1000m in height, no corrorsive gas, liquid , dust

vibation

Below 20Hz 9.80665m/s²1g), 20-50Hz 5.88m/s²0.6g)

enclosure

IP20(Depending on the end customers`s installation environment)

Note: the instantaneous power failure compensation time varies due to the inverter capacity.If a long instataneouspower failure time is required, the external"instantaneous power failure compensation device can be added

 