S900VG
Product description:Power range : 0.4kW-1.5kW 220V
0.7.5kW-2.2kW 380V
Advantage: Compact size
Pulse input/output
High Performance
Item |
Specifications S900VG |
|
Basic function |
Maximum frequency |
400Hz |
Carrier Frequency |
1k to 15kHz; the carrier frequency will be automatically adjusted according to the load characteristics. |
|
Input frequency resolution |
Digital setting: 0.01Hz Analog setting: maximum frequency ×0.1% |
|
Control mode |
V/F control Vector flux control 1 Vector flux control 2 |
|
Startup torque |
G modle: 0.5Hz/180%(Open loop Vector flux control) P model: 0.5Hz/120%(Open loop Vector flux control) |
|
Speed adjustment range |
1:200(Open loop Vector flux control) |
|
Speed stabilization precision |
Open loop Vector flux control:≤±0.5% |
|
Speed stabilization precision |
Open loop Vector flux control:≤±0.3% |
|
Torque response |
≤40ms(Open magnetic flux vector control) |
|
Overload capacity |
G model: 150% rated current 60s; 180% rated current 3s P model: 130% rated current 60s; 150% rated current 3s |
|
Torque hoist |
Automatic torque hoist; manual torque hoist 0.1% to 30.0% |
|
V/F curve |
Linear V/F, Multi-point V/F, and Square V/F |
|
Speed-up and Speed-down curve |
Straight line or S curve speed-up and speed-down mode;Two kinds of speed-up and speed-down time;Speed-up and speed-down time ranges between 0.0s to 3000.0min. |
|
DC brake |
DC brake frequency:0.00Hz to maximum frequency; brake time:0.0s to 36.0s,and brake current value: 0.0% to 100.0%. |
|
Jog control |
Jog frequency range:0.00Hz to 50.00Hz;jog speed-up/speed-down time: 0.0s to 3000.0s. |
|
Simple PLC and MS speed running |
It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. |
|
Built-in PID |
It is easy to realize process-controlled close loop control system. |
|
(AVR)Auto voltage regulation |
It can keep constant output voltage automatically in case of change of mains voltage. |
|
Torque limit and control |
"Shovel" characteristics, the runtime automatic torquelimit, prevent frequent over-current trip; closed loop vectormodel can realize the torque control |
|
Individua-lized function |
Peripherals self-detection upon power-on |
It can conduct safety detections on the peripherals upon power-on, including earth and short circuit detections. |
Shared DC bus function |
It can realize the function that multiple inverters share the DC bus. |
|
JOG key |
Programmable key: Select the command channel switching/forward and reverse rotations/jog operation. |
|
Textile swing frequency control |
Multiple triangular-wave frequency control function. |
|
CBC Function |
Built-CBC algorithm to reduce the probability of voer-current converter reported to improve the whole anti-jamming capabitity. |
|
Timing control |
Timing control function: Setting time range between 0h to 65535h. |
|
Keyboard extension line standard |
Customers can use standard cable extensionon the keyboard |
|
Run |
Running command channel |
Three types of channels:operation panel reference,control terminal reference and serial communication port reference. These channels can be switched in various modes. |
Frequency source |
There are totally ten types of frequency sources, such as digital reference, analog voltage reference, analog current reference, MS speed, PLC, PID, and serial port reference. |
|
Auxiliary frequency source |
There are ten types of auxiliary frequency sources.It can implement micro tuning and synthesis of auxiliary frequency. |
|
Input terminal |
There are five digital input terminals.It can be compatible with active PNP or NPN input mode. There are two analog input terminals,one of which can be used only as voltage input,while the other can be used as voltage or current input. (It can expand one voltage input terminal) |
|
Output terminal |
One digital output terminal One relay output terminal One analog output terminal,with optional 0/4mA to 20mA or 0/2V to 10V. It can realize the output of such physical parameters as setting frequency and output frequency. |
|
Display and Keyboard Operation |
LED display |
The machine has the LED keyboard,and realize parameter settings,status monitoring function. |
LCD display |
Optional, / English prompts content |
|
Parameter Copy |
Keyboard can be copied using the parameters to achive the rapid replication parameter. |
|
Key lock and function selection |
The realization of key part or all of the lock, define the scope of the keys, to prevent misoperation |
|
Others |
Protection function |
It can implement power-on motor short-circuit detection, input/output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection. |
Accessories |
LCD Operation Panel、Brake Uint. |
|
environment |
Using place |
Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt |
Altitude |
1000m, derated when above 1000m |
|
Ambient temperature |
-10 ℃ Celsius to +40 ℃ Celsius (Derated when used in the ambient temperature of 40 ℃ Celsius to 50 ℃ Celsius) |
|
Humidity |
Less than 95%RH, without condensing |
|
Vibration |
Less than 5.9 m/s2(0.6g) |
|
Storage temperature |
-20 Celsius to +60 Celsius |
|
Class of pollution |
2 |
|
Products Standard |
Product implementation of safety standards |
IEC61800-5-1:2007 |
Implementation of EMC standard |
IEC61800-5-1:2007 |