M500
Item |
M500 |
|
Main control fuctions |
Maximum frequency |
Vector control: 0~600Hz |
VF control:0~1200Hz |
||
Carrier Frequency |
1k ~ 15kHz; the carrier frequency will be automatically adjusted according to the load characteristics. |
|
Input frequency |
Digital setting: 0.01Hz |
|
resolution |
Analog setting: maximum frequency ×0.1% |
|
Control mode |
Open loop vector control ; |
|
V/F control. |
||
Start-up torque |
Mode G machine: 0.5Hz/180% (open loop vector control) |
|
Mode P machine: 0.5Hz/120% (Open loop vector control) |
||
Speed adjustment |
1:200(Open loop Vector flux control) |
|
range |
||
Main control fuctions |
Stable speed |
Open loop Vector flux control:≤±0.5% (rated synchronous speed) |
Precision |
||
Stabilization of |
Open loop Vector flux control:≤±0.3% (rated synchronous speed) |
|
speed control |
||
Torque response |
≤40ms(Open magnetic flux vector control) |
|
Overload capacity |
Mode G machine: 150% rated current 60s; 180% rated current 5s |
|
Mode P machine: 130% rated current 60s; 150% rated current 5s |
||
Torque boost |
Automatic torque boost; manual torque boost 0.1% to 30.0% |
|
V/F curve |
Linear V/F, Multi-point V/F, and Square V/F |
|
Speed-up and Speed-down curve |
Straight line or S curve speed-up and speed-down mode; |
|
four kinds of speed-up and speed-down time; |
||
Speed-up and speed-down time ranges from 0.0s |
||
to 3000.0s |
||
DC brake |
DC brake frequency: 0.00Hz ~ maximum frequency; brake time: 0.0s ~ 36.0s, and brake current value: 0.0% to 100.0%. |
|
Jog control |
Jog frequency range:0.00Hz ~ 50.00Hz; |
|
Jog speed-up/speed-down time: 0.0s ~ 3000.0s. |
||
Simple PLC and multi-speed running |
It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. |
|
Built-in PID |
It is easy to realize process-controlled close loop control system. |
|
(AVR)Automatic |
It can keep constant output voltage automatically in case of change of mains voltage. |
|
voltage regulation |
||
Torque limit and control |
"Shovel" characteristics, automatic limit on the torque on running time, preventing frequent over-current trip; closed loop vector mode can realize the torque control |
|
Customized fuctions |
Peripherals self-detection upon |
It can conduct safety detections on the peripherals upon power-on, including earth and short circuit detections. |
power-on |
||
Shared DC bus |
It can realize the function that multiple inverters share the DC bus. |
|
function |
||
JOG key |
Programmable key: Select the forward and reverse rotations/jog operation command. |
|
Customized fuctions |
Traverse frequency control |
Multiple triangular-wave frequency control function. |
Fast current limit function |
With fast current limit algorithm built in to reduce the probability of over-current alarm; to improve the anti-jamming capacity of the whole machine. |
|
Timed control |
Timing control function: Setting time range from 0h to 65535h. |
|
Keyboard extension line standardization |
Customers can use standard cable to extend the keyboard |
|
Operation function |
Running command |
Three types of channels: operation panel given, control terminal given and serial communication port given. These channels can be switched in various ways. |
channel |
||
Frequency source |
Ten types of frequency sources in total: digital given, analog voltage given, analog current given, pulse given, and serial port given. It can be switched in various ways. |
|
Auxiliary frequency source |
Ten types of auxiliary frequency sources in total. It can implement micro tuning and synthesis of auxiliary frequency. |
|
Input terminal |
Five digital input terminals, and seven terminals in maximum (AI1, AI2 can be used as DI terminals), it has compatibility to PNP or NPN input method. |
|
Two analog input terminals, in which AI1 only be used for voltage input, and AI2 can be used as voltage or current input. (if expanded- input or output terminal function is needed, please use M700 series.) |
||
Output terminal |
One digital output terminal (bipolar output) |
|
Two relay output terminal |
||
Two analog output terminals, with optional 0/4mA to 20mA or 0/2V to 10V. It can realize the output of set frequency, output frequency and rotation speed etc. |
||
Display and Keyboard Operate |
LED display |
Display parameter |
LCD display |
Selective parts, Chinese/English to suggest the operation content |
|
Parameter copy |
Use parameter special copy keyboard can copy the parameter quickly |
|
Key lock and function choose |
Lock part of the keyboard or the whole keyboard, definite the function range of some keys to avoid mis-operation. |
|
Protection and select accessories |
protection function |
Short circuit detective of power-on motor, input and output open-phase protection, over-current protection, overvoltage protection, under-voltage protection, over-heat protection, over-load protection etc. |
Selective accessories |
LCD operation panel, brake group etc. |
|
Environment |
Suitable place |
Indoor environment which is against from direct sunlight, dust, corrosive gas, combustible gas, oil mist, vapor, water drop and salt. |
Altitude |
Less than 1000m |
|
Ambient Temperature |
-10ºC ~ +50ºC (derating is required if the natural temperature range is 40ºC ~ 50ºC) |
|
Humidity |
Less than 95%RH, no condensing water drops |
|
Vibration |
Less than 5.9m/ s2 (0.6g) |
|
Storage temperature |
-20ºC ~ +60ºC |
|
Class of pollution |
2 |
|
Product |
Safety standard |
IEC61800-5-1:2007 |
standard |
EMC standard |
IEC61800-3:2005 |