S1100V
Product description: Power range : 0.4kW-5.5kW 220V
0.75kW-630kW 380V
Advantage: Copy parameter function
Pulse input/output
PNP & NPN Avaible
Item |
S1100V |
|
|
Power range |
1.5KW~630KW(normal duty) |
0.75KW~550KW(heavy duty) |
||
|
|
380V(3phase)50/60Hz |
Voltage range |
(-15%...+20%)of rated voltage |
|
|
Control mode |
V/F control |
Vector flux control |
||
Basic function |
Maximum frequency |
600Hz |
Input frequency resolution |
Digital setting: 0.01Hz |
|
Analog setting: maximum frequency ×0.1% |
||
Startup torque |
G modle: 0.5Hz/180%(heavy duty) |
|
P model: 0.5Hz/120%(normal duty) |
||
Speed adjustment range |
1:200(Open loop Vector flux control) |
|
Torque response |
≤40ms(Open magnetic flux vector control) |
|
Overload capacity |
G model: 150% rated current 60s; 180% rated current 3s |
|
P model: 130% rated current 60s; 150% rated current 3s |
||
Torque hoist |
Automatic torque hoist; manual torque hoist 0.1% to 30.00% |
|
V/F curve |
Linear V/F, Multi-point V/F, and Square V/F |
|
Speed-up and Speed-down curve |
Straight line or S curve speed-up and speed-down |
|
mode;Two kinds of speed-up and speed-down time |
||
Acceleration/Deceleration time |
Speed-up and speed-down time ranges between 0.0s to 3000s |
|
DC brake |
DC brake frequency:0.00~400.00Hz |
|
brake time:0.0s to 36.0s,and brake current value: 0.0% to 100.0%. |
||
Jog control |
Jog frequency range:0.00Hz to 50.00Hz; |
|
jog speed-up/speed-down time: 0.0s to 3000.0s. |
||
Simple PLC and MS speed running |
It can realize a maximum of 16 segments speed running |
|
via the built-in PLC or control terminal. |
||
Built-in PID |
It is easy to realize process-controlled close loop control system |
|
voltage regulation(AVR)Auto |
It can keep constant output voltage automatically in case |
|
of change of mains voltage. |
||
|
Torque limit |
"Shovel" characteristics, the runtime automatic torquelimit, prevent frequent |
over-current trip; closed loop vectormodel can realize the torque control |
||
Individua-lized function |
Peripherals self-detection upon power-on |
It can conduct safety detections on the peripherals upon power-on, |
including earth and short circuit detections. |
||
Shared DC bus function |
It can realize the function that multiple inverters share the DC bus. |
|
JOG key |
Programmable key: Select the command channel switching/forward |
|
and reverse rotations/jog operation. |
||
Display and Keyboard |
LED display |
The machine has the LED keyboard,and realize parameter |
settings,status monitoring function. |
||
LCD display |
Optional, / English prompts content |
|
Operation |
Parameter Copy |
Keyboard can be copied using the parameters to achive |
the rapid replication parameter |
||
structure |
Protective |
IP20 |