English Россия Türkiye España

S1100V

Product description: Power range : 0.4kW-5.5kW   220V
                      0.75kW-630kW   380V
Advantage: Copy parameter function
          Pulse input/output
          PNP & NPN Avaible 

Item

                       S1100V

Power range

1.5KW~630KW(normal duty)

0.75KW~550KW(heavy duty)

380V(3phase)50/60Hz

Voltage range

(-15%...+20%)of rated voltage

Control mode

V/F control

Vector flux control

Basic function

Maximum frequency

600Hz

Input frequency resolution

Digital setting: 0.01Hz

Analog setting: maximum frequency ×0.1%

Startup torque

G modle: 0.5Hz/180%(heavy duty)

P model: 0.5Hz/120%(normal duty)

Speed adjustment range

1:200(Open loop Vector flux control)

Torque response

≤40ms(Open magnetic flux vector control)

Overload capacity

G model: 150% rated current 60s; 180% rated current 3s

P model: 130% rated current 60s; 150% rated current 3s

Torque hoist

Automatic torque hoist; manual torque hoist 0.1% to 30.00%

V/F curve

Linear V/F, Multi-point V/F, and Square V/F

Speed-up and Speed-down curve

Straight line or S curve speed-up and speed-down

mode;Two kinds of speed-up and speed-down time

Acceleration/Deceleration time

Speed-up and speed-down time ranges between 0.0s to 3000s

DC brake

DC brake frequency:0.00~400.00Hz  

brake time:0.0s to 36.0s,and brake current value: 0.0% to 100.0%.

Jog control

Jog frequency range:0.00Hz to 50.00Hz;

jog speed-up/speed-down time: 0.0s to 3000.0s.

Simple PLC and MS speed running

It can realize a maximum of 16 segments speed running

via the built-in PLC or control terminal.

Built-in PID

It is easy to realize process-controlled close loop control system

voltage regulation(AVR)Auto

It can keep constant output voltage automatically in case

of change of mains voltage.

Torque limit
and control

"Shovel" characteristics, the runtime automatic torquelimit, prevent frequent

over-current trip; closed loop vectormodel can realize the torque control

Individua-lized function

Peripherals self-detection upon power-on

It can conduct safety detections on the peripherals upon power-on,

including earth and short circuit detections.

Shared DC bus function

It can realize the function that multiple inverters share the DC bus.

JOG key

Programmable key: Select the command channel switching/forward

and reverse rotations/jog operation.

Display and Keyboard

LED display

The machine has the LED keyboard,and realize parameter

settings,status monitoring function.

LCD display

Optional, / English prompts content

Operation

Parameter Copy

Keyboard can be copied using the parameters to achive

the rapid replication parameter

   structure

Protective

IP20

 

prve:S2800E
next:M500